{"product_id":"premiersync-700r","title":"PremierSync - 700R","description":"\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003e\u003cstrong\u003ePremierSync-700R\u003c\/strong\u003e controls the selected deaerators, condensate\/surge tanks, and boilers from one balance-of-plant panel. Use the three-step configurator alongside this description to build your request.\u003c\/p\u003e\n\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eBalance Of Plant, Feedwater \u0026amp; Tank Control\u003c\/h3\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003e\u003cstrong\u003eSimplify boiler plant operation with integrated balance-of-plant controls.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003ePremierSync brings essential boiler plant support functions together in one configurable control panel. From plant demand management and lead\/lag sequencing to feedwater pressure regulation and tank level control, PremierSync provides an integrated control solution tailored to your application.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eFlexible Feedwater And Tank Control\u003c\/h3\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eConfigure control functions for deaerators, condensate\/surge tanks, and boiler feedwater systems. Available functions include:\u003c\/p\u003e\n\u003cul style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 20px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003ePlant Master Control:\u003c\/strong\u003e boiler plant demand management.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eLead\/Lag Sequencing:\u003c\/strong\u003e boiler start\/stop sequencing and duty rotation. Select Plant Master, Lead\/Lag, or Both to suit your application.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eTank Level Control:\u003c\/strong\u003e level monitoring, makeup water control (tank level), and modulating valve commands.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eFeedwater Pump Control:\u003c\/strong\u003e pump start\/stop, lead\/lag sequencing, and variable-speed drive (VFD) control signals.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003ePressure Control:\u003c\/strong\u003e feedwater header pressure regulation and selected tank pressure monitoring. Deaerator tank pressure and feedwater pressure are separate measurements and control functions.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eSystem Monitoring:\u003c\/strong\u003e tank levels, pressures, temperatures, pump status, and operating conditions as configured.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003ePlant Integration:\u003c\/strong\u003e interfaces with combustion controls and other plant automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eSelect the functions needed for your application. SHC reviews and confirms the final operating sequence, control interlocks, instrumentation requirements, and system interfaces during project engineering.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eStandard Base Configuration\u003c\/h3\u003e\u003cul style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 20px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e15-inch touchscreen (HMI); optional 10-inch downgrade or 19-inch upgrade.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eControl-panel functions for the equipment and operating arrangements you select.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eLogic-controller and HMI programming, including custom HMI graphics for the selected application.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eStandard design documentation: control-system wiring diagram, general arrangement drawing, I\/O list, and controls narrative.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eAutomatic calculation of the defined input\/output (I\/O) signals and required cards.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eOptional enclosure, touchscreen, network, power, and spare I\/O capacity upgrades.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eFinal controller hardware, enclosure size, interfaces, and scope confirmed by SHC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eEquipment, Controls And Connections\u003c\/h3\u003e\n\u003cul style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 20px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eDeaerators:\u003c\/strong\u003e select up to 2 tanks. Included measurements are tank pressure, tank level, tank temperature, and feedwater pressure.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eCondensate\/Surge Tanks:\u003c\/strong\u003e select up to 2 tanks. Included measurements are tank level and tank temperature.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eTank pumps and valves:\u003c\/strong\u003e select up to 6 pumps and 2 makeup water valves (tank level control) per tank. Deaerators also offer recirculation and pegging-steam control. Tank instruments and valves connect directly to the panel using field wiring. Settings apply to every tank of the same type; use Project Notes to describe different arrangements.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003ePump-drive connections:\u003c\/strong\u003e choose Hardwired or Ethernet. Hardwired pumps include start, running-feedback, and analog-feedback signals. Hardwired VFDs also include a speed command.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eBoilers:\u003c\/strong\u003e select up to 10 boilers and choose Steam or Hot Water. Select Plant Master to control plant demand, Lead\/Lag to sequence boilers and rotate their duty, or Both for demand control and sequencing.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eBoiler connections:\u003c\/strong\u003e choose Hardwired, Ethernet, or Modbus. Hardwired connections include firing-rate command, firing-rate feedback, running feedback, and four process measurements.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003ePlant Master input:\u003c\/strong\u003e plant header pressure for Steam, or water outlet temperature for Hot Water. Header steam flow or water flow is a separate measurement, counted once per panel.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eNetwork signals:\u003c\/strong\u003e Ethernet and Modbus values do not use physical I\/O channels. Selecting Modbus automatically adds the protocol-conversion option once per panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eThe Automatic I\/O And Card Schedule shows the required cards. The Defined Signal Breakdown lists each expected signal and its connection type. SHC confirms the final signal list and network compatibility.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eI\/O Capacity\u003c\/h3\u003e\u003cul style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 20px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e16 channels per digital input card and relay output card.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e16 channels per analog input card; 8 channels per analog output card.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003eRequired card counts round up for each signal type. Extra cards add spare capacity.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eMaximum 16 total I\/O cards per panel\u003c\/strong\u003e, including extra cards. If all slots are used, unused extra-card choices are hidden; selected extra cards can still be reduced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eWhat Is Included And What Requires A Separate Quote?\u003c\/h3\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eThe online configurator prices the PremierSync control panel and your selected options. Tanks, pumps, field instruments, control valves, VFDs, equipment sizing, and field installation are not included unless specifically identified in an SHC quotation.\u003c\/p\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eProduct photographs illustrate completed applications and may show equipment outside the configured scope.\u003c\/p\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eThe panel can provide pump-speed commands without supplying the VFD itself. If you would like SHC to supply pump drives, select that request and enter the motor horsepower, supply voltage, and number of phases. Drives and additions without a published price require a separate formal quotation. Sizing assistance is available on request.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eNeed A Custom Solution?\u003c\/h3\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eFor condensate return arrangements beyond the tank controls in this configurator, hot wells, water softeners, air handling equipment, or other specialized balance-of-plant applications, \u003ca href=\"\/pages\/contact\"\u003econtact SHC for a project-specific quotation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eAdditional Systems Available By Formal Quotation\u003c\/h3\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eThe following control and monitoring functions can be added to a PremierSync system upon formal quotation request. They are outside the standard online configuration and are not included in its budgetary price. SHC will confirm the control scope, interfaces, I\/O, hardware, and pricing for your application.\u003c\/p\u003e\n\u003cul style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 20px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eFuel Supply System:\u003c\/strong\u003e manages natural gas supply and fuel-oil system distribution.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eCompressed Air System:\u003c\/strong\u003e controls plant air compressors and instrument air.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eWater Treatment:\u003c\/strong\u003e monitors reverse-osmosis (RO) systems, water softeners, and chemical treatment.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eSteam Distribution:\u003c\/strong\u003e controls steam headers, pressure-reducing stations, and auxiliary steam.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eElectrical Distribution:\u003c\/strong\u003e monitors motor control centers (MCCs), breakers, transformers, and auxiliary power.\u003c\/li\u003e\n\u003cli style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eAuxiliary Equipment:\u003c\/strong\u003e controls ventilation, sump pumps, and other supporting equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003e\u003ca href=\"\/pages\/contact\"\u003eRequest a formal quotation from SHC\u003c\/a\u003e to include these systems. Field-equipment supply and sizing are included only when expressly stated in the quotation.\u003c\/p\u003e\n\u003ch3 style=\"font-family:inherit;font-size:20px;font-weight:700;line-height:1.35;color:#17683f;margin:28px 0 12px;\"\u003eEngineering And Quotation\u003c\/h3\u003e\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eApplication-specific safety interlocks, including low-level protection and pump permissives, must be defined during engineering. Variable-speed feedwater pumps may require minimum-flow protection or recirculation; SHC reviews these requirements during engineering rather than assuming they are included as standard configured functions.\u003c\/p\u003e\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eThe I\/O review lists the defined signals; it is a preliminary schedule. Additional feedback, faults, resets, and interlocks are excluded unless listed. SHC confirms the final signal list, hardware, enclosure, compatibility, and price before an order is placed.\u003c\/p\u003e\u003cp style=\"font-family:inherit;font-size:15px;line-height:1.7;margin:0 0 16px;\"\u003eAdd your configuration to the quote cart to set quantities, download a PDF, or send it to SHC for review. \u003ca href=\"\/pages\/contact\"\u003eContact SHC\u003c\/a\u003e for help choosing options, instrumentation, drives, or recommended spare parts.\u003c\/p\u003e","brand":"Stanyan Hill Controls","offers":[{"title":"Default Title","offer_id":68267859738925,"sku":null,"price":7000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0965\/5595\/8573\/files\/premiersync-700r-example-v2.png?v=1794247938","url":"https:\/\/stanyanhill.shop\/products\/premiersync-700r","provider":"Stanyan Hill Controls","version":"1.0","type":"link"}